We quote a lot of commercial kitchen equipment — ranges, wok burners, combi ovens, fryers, griddles — into hotels, catering companies and institutional canteens. Roughly half the buyers arrive already convinced they know whether they want gas or induction. Most of them are deciding on the wrong criteria. They argue about cooking performance, which in a professional kitchen is a wash, and skip the three things that actually derail an installation: the incoming electrical supply, the local gas pressure and quality, and the spare-parts path for the next decade.
The electrical service decides more projects than the chef does
Induction is an electrical load problem before it is a cooking problem. A single 3.5 kW countertop wok unit is nothing. A full induction line — four wok burners at 8 kW, two ranges at 10 kW, a couple of fryers — can put 60 to 80 kW of connected load in a kitchen that was designed for 30. That is not a plug-and-play upgrade. It means a new distribution board, new cabling sized for the actual continuous draw, and often a transformer upgrade from the utility.
This is where a lot of export projects quietly go wrong. The buyer's site has a 3-phase 400 V supply at, say, 100 A per phase, which sounds generous until you convert it: 400 V × 100 A × 1.732 is roughly 69 kVA, and you cannot load it to the brim. Put a 70 kW induction kitchen on that and the main breaker trips the first time everyone fires up at service. On paper the kitchen fits; in practice it does not.
The other electrical trap is supply voltage and frequency. A unit built for 230 V single-phase will run poorly on a 208 V supply common in parts of North America and Japan, and it will not run at all on 60 Hz equipment designed for 50 Hz without a control-board change. If your destination market is mixed — and in the Middle East and Africa it very often is — specify the actual nameplate voltage range you need, not the nominal voltage. Ask the factory what tolerance the heating control accepts. "220–240 V" and "200–250 V" are different machines with different price tags.
Gas is cheap to install until the local network is the problem
Gas equipment looks like the easy answer. The burners are simple, the purchase price is lower per kW of cooking power, and any competent plumber can hook it up. Where it stops being easy is the gas itself. The same range that performs beautifully on natural gas at a stable 20 mbar will behave like a different appliance on LPG, and differently again on the low-pressure natural gas that some markets actually deliver.
Jet sizing is the issue. Burners are calibrated for a specific gas family and a specific supply pressure. Ship a natural-gas calibrated range to a site running LPG and the flame is wrong — too short, too hot at the burner face, or yellowing and sooting. It can be fixed by changing injectors, but only if the factory shipped the right injector kit and your installer knows to do it. That is a five-dollar part and a two-week delay if it is missing. We now ship LPG and NG injector sets with every gas appliance and put the conversion table in the manual, and we still get calls where someone installed it on the wrong set.
Then there is ventilation. Gas combustion inside a kitchen produces moisture and CO₂, and the extract hood, make-up air and flue path all have to be designed for the burner load. Induction produces virtually none of that, which cuts the ventilation load significantly — in a hot climate that is a genuine operating saving, because you are not paying to extract hot combustion gases and then paying again to cool the make-up air.
| Factor | Induction | Gas |
|---|---|---|
| Purchase price per kW | Higher, roughly 1.5–2.5× | Lower, mature and commoditised |
| Installation | Electrical service upgrade often required | Gas line, flue and ventilation required |
| Energy cost per hour | Usually lower — 85–90% of energy into the pan | Higher — 40–55% useful heat, rest is losses |
| Kitchen heat load | Low; no combustion gases | High; affects AC sizing and staff comfort |
| Spare parts | Power boards, IGBT modules, coils | Valves, thermocouples, jets — universal |
| Certification focus | Electrical safety, EMC, harmonic limits | Gas safety, CE Gas Appliance Regulation, local gas marks |
The running cost argument, with real numbers
Induction usually wins on energy, and the margin is bigger than the brochure suggests. A gas burner puts roughly 40–55% of its input into the pan; the rest heats the kitchen. Induction transfers 85–90%. So even where gas is cheaper per kWh — and in many markets it is not, once you account for cylinder delivery in remote areas — induction often still costs less per hour of cooking.
But do not present that to your customer as a blanket claim. In markets with subsidised gas and expensive electricity, gas wins on operating cost and there is nothing to argue about. In markets with unreliable electricity and frequent brownouts, a gas kitchen keeps cooking when the grid does not. We have supplied both and we have no interest in pushing one over the other; we push whatever the site can actually support. The calculation is: measure the gas price per unit, measure the electricity tariff including demand charges, apply the efficiency figures, and then check the supply capacity. Buyers who skip the last step are the ones who buy 60 kW of induction for a 20 kW service.
Watch the demand charge: In many commercial tariffs the electricity bill is not just kWh. Peak demand charges can add 20–40% to the effective cost of an all-electric kitchen. Ask the end user for a recent utility bill before you promise an induction line will be cheaper to run.
Certification: two completely different paperwork trails
Electrical and gas appliances travel through different regulatory channels, and buyers who treat them the same get stuck at customs. Induction equipment needs electrical safety approval, EMC compliance, and — for larger units — harmonic current limits, because a bank of high-power induction units is a genuinely unfriendly load for a weak grid. For Europe that means the relevant directives and a CE declaration; for Gulf markets it is typically G-mark plus local conformity; for North America it is UL or ETL listing, and the listing is per model, not per family.
Gas equipment needs gas-safety approval instead, and the standard is market-specific: CE under the Gas Appliance Regulation in Europe, and in many other markets a national gas mark that a European certificate will not satisfy. If your destination requires a local gas approval, expect the factory to need a sample unit tested in-country, and budget six to twelve weeks. Neither trail is a reason to avoid a supplier, but a supplier who cannot tell you which certificate applies to your destination is a supplier who has never shipped that product there.
Spare parts and service are what you are really buying
A commercial kitchen is a production line. When the wok burner in a hotel kitchen goes down during dinner service, the cost is not the part — it is the covers you cannot serve. This is where induction and gas diverge sharply on the service side.
Gas parts are close to universal: thermocouples, gas valves, jets, igniters. Any refrigeration-and-appliance technician in almost any market can source and fit them, often from local stock. Induction parts are electronics. The power board, the IGBT module and the coil are model-specific, and a failed board usually has to come from the original factory. That is fine if you plan for it; it is a disaster if you do not. For any induction project we quote, we push the buyer to take a spares kit with the order — one power board and one control board per three units is the ratio we usually recommend — and we insist on the wiring diagram and fault codes, because a technician cannot diagnose a board he cannot read.
We also ask buyers to name the service technician before the equipment ships. Not a company — a person, with a phone number. If nobody at the destination can open the unit and diagnose a fault, the equipment is only as good as its warranty, and warranty shipping costs across an ocean frequently exceed the value of the part.
The quote should tell you which one to buy
A competent kitchen equipment quote is not a price list. It includes the connected electrical load and the recommended supply, the gas type and pressure the units are calibrated for, the certification held for that specific destination market, the spares kit, the installation and ventilation requirements, and the commissioning steps. If a quote is a spreadsheet of model numbers and prices with no service data, you are looking at a trading company that will disappear the moment the container lands.
Induction vs gas is not a technology debate. It is a site survey. Find out what the electrical supply can actually deliver, what gas the local network actually provides at what pressure, what the utility bill looks like, and who will service the equipment in year four. Those four answers decide the kitchen. Everything after that is shopping.