We quote split units, multi-splits, VRF systems and portable AC into the Middle East, Africa and Southeast Asia, and the refrigerant question comes up on almost every order now — sometimes as a genuine spec decision, more often because a customer read one article about R32 and assumed it was mandatory everywhere. It is not. The right refrigerant depends on the destination market's regulations, the size of the charge in each circuit, and how the units will be serviced for the next decade.

There is no single best refrigerant. There is only the one that fits the rules in the country you are importing into and the service reality on the ground. Let us go through the three you will be offered.

R410A: still the workhorse, and still going away

R410A has been the default for residential and light commercial AC for around two decades. It is a blend of R32 and R125, it runs at high pressure, and it has a Global Warming Potential (GWP) of roughly 2,088 — meaning one kilogram of R410A released has the climate impact of over two tonnes of CO2. That number is the whole problem.

Under the Kigali Amendment to the Montreal Protocol, most markets are on a schedule to cut hydrofluorocarbon (HFC) consumption by 80-85% between their baseline and the 2040s. The EU F-gas Regulation is further along, with a quota system that has already pushed R410A prices up and made certain equipment illegal to place on the market. The US AIM Act is running a similar glide path. In practice this means three things for an importer:

New equipment has an expiry. Depending on the market and the equipment type, R410A units will eventually be restricted from new sale. If your destination is the EU, that date is closer than most buyers think. If it is a market without a firm HFC schedule, R410A is still straightforwardly legal and available.

The gas gets more expensive. Quota systems reduce supply. Refrigerant that was a cheap consumable becomes a line item you quote carefully during servicing. Buyers in Europe have already seen R410A cylinder prices climb year on year.

Stock and spares still work. This is the argument for R410A in markets without strict rules: every technician knows it, every supplier stocks it, and the equipment is proven and cheap. If you are importing into a market with no HFC schedule and a technician base trained on R410A, forcing R32 for "green" reasons creates a servicing problem you will pay for later.

Multi-split air conditioning outdoor unit
A multi-split outdoor unit. The refrigerant charge per circuit, not per system, is what most charge-limit rules actually regulate.

R32: lower GWP, but it is flammable — this is the part buyers miss

R32 is a single-component refrigerant with a GWP of about 675, roughly a third of R410A. It has better volumetric efficiency, so a system with R32 often needs a slightly smaller charge for the same cooling. Many manufacturers now build the same chassis for both R410A and R32 with different compressors and labels.

What buyers routinely do not know is that R32 is classified A2L — mildly flammable. It is not the same risk category as propane, but it is not inert either. A2L refrigerants burn, just slowly and with a low flame speed, and the regulations that apply to them are different from the ones applied to R410A.

In practice, an A2L classification triggers:

Charge limits per circuit. Most A2L standards cap the refrigerant charge in a single circuit based on room volume, the type of occupancy, and where the unit sits. A wall unit in a small bedroom has a much lower permitted charge than the same unit in an open office. If your project is a small hotel room or a sealed plant room, the charge limit can rule out R32 entirely for that application.

Labeling and installation requirements. Units must carry the A2L warning markings, and installers are expected to be trained on flammable refrigerant handling. In markets where that training does not exist yet, an R32 unit may be legal but effectively unserviceable.

Transport and storage rules. Shipping and warehousing A2L-charged equipment can bring additional handling requirements depending on the market. Ask your forwarder before you assume a container of R32 units ships exactly like a container of R410A units.

Do not accept "R32 is the new standard" as a spec. It is a lower-GWP option with real handling requirements. Whether it is the right choice depends on the destination's rules, the room sizes, and whether the local service network is trained for it. In a market with no A2L framework and no trained installers, R410A may still be the safer commercial decision even though it is worse on paper.

R290: natural refrigerant, tiny charges, narrow use

R290 is propane — a natural refrigerant with a GWP of 3, essentially negligible. It is the darling of the environmental side of the industry and it genuinely has a place, but that place is narrow. Propane is A3 — highly flammable, the same category as the gas in a barbecue cylinder.

Because of that, R290 is used in systems with very small charges: portable AC, small monobloc units, some commercial display cabinets, and heat pumps where the charge is engineered down to a few hundred grams. The charge limit rules are strict — often measured in a couple of hundred grams per circuit — and the equipment must be designed around that from the ground up. You cannot simply retrofit an R290 compressor into a conventional split and call it green.

For most export AC projects we handle, R290 is not on the table. It shows up in specific product categories and in markets with strong natural-refrigerant incentives. If a supplier offers you an R290 split for general use, ask for the charge per circuit and the standard under which it is permitted — the answers are usually where the conversation ends.

RefrigerantGWPSafety classWhere it fits
R410A~2,088A1 (non-flammable)Markets without strict HFC rules; proven service base; smaller charges not a concern
R32~675A2L (mildly flammable)Markets pushing lower GWP with A2L framework and trained installers
R290~3A3 (highly flammable)Small-charge equipment: portables, monoblocs, some display and heat pump units

What to pin down before you order

The refrigerant choice is not a checkbox on the product page. It changes the compressor, the label, the charging equipment, the documentation and the spare-parts path. Before you confirm an AC order for export, get answers to the following in writing:

1. What refrigerant, exactly, and what is the charge per circuit? Not per system — per circuit. On a multi-split or VRF the charge is split across circuits, and the charge-limit rules apply per circuit. A unit that is fine as a single split may be over the limit on one branch of a multi-split.

2. What does the destination market require? Confirm the HFC schedule, the flammable-refrigerant framework (if any), and any labelling or certification requirement. This is the buyer's job, not the factory's — the factory sells to twenty countries and is not going to police your regulatory position.

3. Is the local service base equipped for it? Ask whether the technicians who will service the units have the gauges, the training and the gas for that refrigerant. This is the question that quietly decides whether a technically superior choice becomes a fleet of dead units in year three.

4. What is the spare-parts path? Compressors, valves and coils are refrigerant-specific. Confirm the parts supply for the refrigerant you choose, and confirm whether the same parts are still produced in five years. R410A parts are everywhere today; the supply curve on legacy HFC parts should be part of your decision.

5. What is the documentation set? Look for the refrigerant designation on the nameplate, the relevant safety-class labelling, the charging instructions, and any locally required conformity document. Safety-class labelling is not optional on A2L or A3 equipment.

Heat pump outdoor unit
Heat pumps increasingly use A2L or natural refrigerants with engineered-down charges. On this product family, the refrigerant and the charge are part of the design, not a substitution.

The honest picture for a buyer

If you are importing into the EU, R410A new equipment is on a shrinking runway and R32 is the mainstream transition, with the A2L handling requirements now a normal part of the job. If you are importing into a market with no firm HFC schedule and a technician base trained on R410A, R410A remains the pragmatic choice — legal, cheap, serviceable — and no amount of marketing makes R32 the right answer there yet. If you are buying portables or monoblocs, expect R290 to appear, and check the charge per circuit against the room size.

The mistake we see most often is buying on the refrigerant name alone — choosing R32 because it reads as "greener" without checking the A2L charge limit or the local installer training, or clinging to R410A because it is familiar without checking whether new units will still be placeable on the market in the destination. Neither is a strategy. Both are corrected by asking five questions before the order, not after the container lands.

The refrigerant is not the cheapest part of an AC unit. It is just the part that decides the next ten years.

If you are sourcing split, multi-split or VRF systems for an export project, send us the destination market, the room sizes and the cooling load. We will match the refrigerant to the rules and the service reality, and quote the units with the documentation the shipment needs.